Russian Medical Inquiry
(RMZh. Meditsinskoe Obozrenie) ISSN 2587-6821 (Print), 2686-9918 (Online)

A new method to collect unstimulated tears in clinical settings

VAK

Scopus

E-libraryDimensions

russian citation indexULRICHS

roaddoaj

CyberleninkaGoogle Scholar

vinitiResearch4life

MendeleyScilit

РГБWhite list




Open accessCrossrefAntiplagiat

RMJ.ru




DOI: 10.32364/2311-7729-2026-26-1-9

T.Yu. Matnenko1, O.I. Lebedev1, S.V. Barinov1, A.N. Zolotov1, Yu.I. Chulovskyi1, D.G. Novikov1, N.A. Kirichenko1, M.A. Korobko1, O.G. Vyhodtseva2

1Omsk State Medical University, Omsk, Russian Federation

2V.P. Vykhodtsev Clinical Ophthalmological Hospital, Omsk, Russian Federation

Background: actually, possibilities of tear collection in clinical settings, its composition and diagnostic capabilities are widely studied. A Schirmer's test strip method of tear sampling became the most common. However, this method has some disadvantages. There are a lot of patented methods for tear fluid collection, most of them are time-consuming, require special devices, and cause discomfort in patients.

Aim: to evaluate a new method to collect unstimulated tears in clinical settings.

Materials and Methods: tear sampling was performed in 55 healthy volunteers without a pathology of the anterior segment of the eye. A new proposed method of tear collection with an applicator and the closest analogue (i. e., tear extraction with three filter paper disks) were used. To assess the study tolerability, an original patient questionnaire consisting of 9 questions and 5 objective signs was used. To quantify tears obtained by the two methods, a biochemical analysis was performed to evaluate VEGF-A level.

Results: a subjective assessment of the method was obtained. The applicator method was associated with pre-test apprehension, burning, discomfort, and foreign body feeling during the procedure. More participants experienced redness, dryness, and burning during the disk test. Applicators had an advantage in obtaining consent for a repeat testing. Hyperemia, frequent blinking movements, and reflex tears from the paired eye were more common during the disk test.

The quantity of tears collected with applicators turned out to be sufficient for their quantification. Superior means were demonstrated by the second method (i. e., the disk test). Half of the results showed the same bias indicating the same informative value of the methods, but different values of the norm for them.

Conclusions: There is no single standard method to collect tears for biochemical analysis. The proposed tear sampling method with applicators does not stimulate lacrimation, it is safe, easy-to-use and reproducible. Tear volume obtained by the proposed method proved to be sufficient to evaluate VEGF-A level.

Keywords: tear fluid sampling, Schirmer strips, filter paper, applicators, tear, VEGF, tear collection.

For citation: Matnenko T.Yu., Lebedev O.I., Barinov S.V., Zolotov A.N., Chulovskyi Yu.I., Novikov D.G., Kirichenko N.A., Korobko M.A., Vyhodtseva O.G. A new method to collect unstimulated tears in clinical settings. Russian Journal of Clinical Ophthalmology. 2026;26(1):58–64 (in Russ.). DOI: 10.32364/2311-7729-2026-26-1-9

ABOUT THE AUTHORS:

Tatiana Yu. Matnenko — C. Sc. (Med.), Assistant Professor, Assistant Professor of the Department of Ophthalmology, Omsk State Medical University; 12, Lenin str., Omsk, 644099, Russian Federation; ORCID iD 0000-0003-0859-5435

Oleg I. Lebedev— Dr. Sc. (Med.), Professor, Dean of the Faculty of General Medicine, Head of the Department of Ophthalmology, Omsk State Medical University; 12, Lenin str., Omsk, 644099, Russian Federation; ORCID iD 0000-0001-8190-4121

Sergei V. Barinov — Dr. Sc. (Med.), Professor, Head of the Department of Obstetrics and Gynecology No. 2, Omsk State Medical University; 12, Lenin str., Omsk, 644099, Russian Federation; ORCID iD 0000-0002-0357-7097

Alexander N. Zolotov — C. Sc. (Med.), Assistant Professor, Senior Scientific Officer at the Central Scientific Research Laboratory, Assistant Professor of the Department of Pathophysiology, Omsk State Medical University; 12, Lenin str., Omsk, 644099, Russian Federation; ORCID iD 0000-0002-6775-323X

Yurii I. Chulovskyi — C. Sc. (Med.), Assistant Professor, Assistant Professor of the Department of Obstetrics and Gynecology No. 2, Omsk State Medical University; 12, Lenin str., Omsk, 644099, Russian Federation; ORCID iD 0000-0002-4806-6880

Dmitryi G. Novikov — C. Sc. (Med.), Assistant Professor, Assistant Professor of the Department of Clinical Laboratory Diagnostics of Additional Professional Education, Head of the Central Scientific Research Laboratory, Omsk State Medical University; 12, Lenin str., Omsk, 644099, Russian Federation; ORCID iD 000-0002-4339-2222

Nikolay A. Kirichenko — Teaching Assistant at the Department of Clinical Laboratory Diagnostics of Additional Professional Education, Junior Scientific Officer at the Central Scientific Research Laboratory, Omsk State Medical University; 12, Lenin str., Omsk, 644099, Russian Federation; ORCID iD 0000-0002-8411-0973

Maria A. Korobko — Resident of the Department of Ophthalmology, Omsk State Medical University; 12, Lenin str., Omsk, 644099, Russian Federation; ORCID iD 009-0005-1727-7377

Olga G. Vykhodtseva — Head of Microsurgical Department No. 1, V.P. Vykhodtsev Clinical Ophthalmological Hospital; 60, Lermontov str., Omsk, 644024, Russian Federation; ORCID iD 0000-0002-2871-641X

Financial Disclosure: no authors have a financial or property interest in any material or method mentioned.

There is no conflict of interest.

Received 15.04.2025.

Revised 14.05.2025.

Accepted 06.06.2025.

References
1. Stevenson W., Pugazhendhi S., Wang M. Is the main lacrimal gland indispensable? Contributions of the corneal and conjunctival epithelia. Surv Ophthalmol. 2016;61(5):616–627. DOI: 10.1016/j.survophthal.2016.02.006
2. Winiarczyk M., Biela K., Michalak K. et al. Changes in tear proteomic profile in ocular diseases. Int J Environ Res Public Health. 2022;19(20):13341. DOI: 10.3390/ijerph192013341
3. Ma J.Y.W., Sze Y.H., Bian J.F., Lam T.C. Critical role of mass spectrometry proteomics in tear biomarker discovery for multifactorial ocular diseases (Review). Int J Mol Med. 2021;47(5):83. DOI: 10.3892/ijmm.2021.4916
4. Martínez V., Franklin V., Wolffsohn J.S. The potential influence of Schirmer strip variables on dry eye disease characterisation, and on tear collection and analysis. Cont Lens Anterior Eye. 2018;41(1):47–53. DOI: 10.1016/j.clae.2017.09.012
5. Huang Z., Du C.X., Pan X.D. The use of in-strip digestion for fast proteomic analysis on tear fluid from dry eye patients. PLoS One. 2018;13(8):e0200702. DOI: 10.1371/journal.pone.0200702
6. Wong T.T., Zhou L., Li J. et al. Proteomic profiling of inflammatory signaling molecules in the tears of patients on chronic glaucoma medication. Invest Ophthalmol Vis Sci. 2011;52(10):7385–7391. DOI: 10.1167/iovs.10-6532
7. Valencia E., García M., Fernández-Vega B. et al. Targeted Analysis of tears revealed specific altered metal homeostasis in age-related macular degeneration. Invest Ophthalmol Vis Sci. 2022;63(4):10. DOI: 10.1167/iovs.63.4.10
8. Rentka A., Koroskenyi K., Harsfalvi J. et al. Evaluation of commonly used tear sampling methods and their relevance in subsequent biochemical analysis. Ann Clin Biochem. 2017;54(5):521–529. DOI: 10.1177/0004563217695843
9. Nguyen-Khuong T., Everest-Dass A.V., Kautto L. et al. Glycomic characterization of basal tears and changes with diabetes and diabetic retinopathy. Glycobiology. 2015;25(3):269–283. DOI: 10.1093/glycob/cwu108
10. Kaštelan S., Braš M., Pjevač N. et al. Tear biomarkers and Alzheimer's disease. Int J Mol Sci. 2023;24(17):13429. DOI: 10.3390/ijms241713429
11. Лобанова О.С. Инновационный способ диа­гностики и мониторинга лечения болезни глазной поверхности в практике врача-офтальмолога. Современная оптометрия. 2010;2:32–35.Lobanova O.S. Innovative method in dry eye diagnosis and monitoring of its treatment. Sovremennaya optometriya. 2010;2:32–35 (in Russ.).
12. Keech A., Senchyna M., Jones L. Impact of time between collection and collection method on human tear fluid osmolarity. Curr Eye Res. 2013;38(4):428–436. DOI: 10.3109/02713683.2013.763987
13. Часнык В.Г., Кононов А.В., Бржеский В.В. и др. Протеомный профиль слезы в диа­гностике поражения глаз при ревматических заболеваниях у детей. Российская детская офтальмология. 2023;4:11–22. DOI: 10.25276/2307-6658-2023-4-11-22Chasnyk V.G., Kononov A.V., Brzheskij V.V. et al. Proteomic tears profile in the diagnosis of eye damage in children with rheumatic diseases. Rossiyskaya detskaya oftalmologiya. 2023;4(44):11–22 (in Russ.). DOI: 10.25276/2307-6658-2023-4-11-22
14. Тахауова Л.Р., Кривошеина О.И., Попов И.А. Протеомный анализ слезы как перспективный метод диа­гностики синдрома сухого глаза. Офтальмология. 2024;21(2):264–269. DOI: 10.18008/1816-5095-2024-2-264-269Takhauova L.R., Krivosheina O.I., Popov I.A. Proteomic Analysis of Tears as a Promising Method for Diagnosing Dry Eye Syndrome. Ophthalmology in Russia. 2024;21(2):264–269 (in Russ.). DOI: 10.18008/1816-5095-2024-2-264-269
15. Jones G., Lee T.J., Glass J. et al. Comparison of different mass spectrometry workflows for the proteomic analysis of tear fluid. Int J Mol Sci. 2022;23(4):2307. DOI: 10.3390/ijms23042307
16. Markoulli M., Gokhale M., You J. Substance P in Flush Tears and Schirmer Strips of Healthy Participants. Optom Vis Sci. 2017;94(4):527–533. DOI: 10.1097/OPX.0000000000001040. Erratum in: Optom Vis Sci. 2019;96(5):384. DOI: 10.1097/OPX.0000000000001379
17. Мухамадиев Р.О., Дехканов Т.Д., Блинова С.А. и др. Возрастные особенности кристаллизации слезы у здоровых лиц. Вестник врача. 2017;4:27–31.Mukhamadiev R.O., Dehkanov T.D., Blinova S.A. et al. Age features of crystallization tears healthy persons. Vestnik Vracha. 2017;4:27–31 (in Russ.).
18. Dartt D.A., Willcox M.D. Complexity of the tear film: importance in homeostasis and dysfunction during disease. Exp Eye Res. 2013;117:1–3. DOI: 10.1016/j.exer.2013.10.008
19. Матненко Т.Ю. Пробирка для нестимулированного сбора слезной жидкости. Патент на полезную модель RU240377U1.Matnenko T.Yu. Unstimulated tear collection tube. Utility model patent RU240377U1.
20. Атькова Е.Л., Ярцев В.Д., Хесина З.Б. Способ получения слезной жидкости для химико-аналитического исследования. Патент RU2743330С1. Опубл. 17.02.2021, Бюл. № 5.Atkova E.L., Yartsev V.D., Khesina Z.B. Lachrymal fluid obtaining method for chemical analysis. Patent RU2743330С1. Date of publication: 17.02.2021, Bull. № 5 (in Russ.).
21. Pieczyński J., Szulc U., Harazna J. et al. Tear fluid collection methods: Review of current techniques. Eur J Ophthalmol. 2021;31(5):2245–2251. DOI: 10.1177/1120672121998922
22. Pieczyński J., Kiewisz J. Usefulness of Schirmer's tear strips and borosilicate glass tubes in chemical analysis of human tear fluid: A practical check in VEGF detection. Eur J Ophthalmol. 2024;34(6):1843–1846. DOI: 10.1177/11206721241238879
23. Ablamowicz A.F., Nichols J.J. Concentrations of MUC16 and MUC5AC using three tear collection methods. Mol Vis. 2017;23:529–537. PMID: 28761326
24. Gupta S., Shankar S., Bhatta S. et al. Comparison of tear matrix metalloproteinase 9 (MMP-9) estimation with Schirmer's test in ocular surface disorders. Rom J Ophthalmol. 2024;68(3):225–232. DOI: 10.22336/rjo.2024.42
25. Bachhuber F., Huss A., Senel M., Tumani H. Diagnostic biomarkers in tear fluid: from sampling to preanalytical processing. Sci Rep. 2021;11(1):10064. DOI: 10.1038/s41598-021-89514-8
26. Denisin A.K., Karns K., Herr A.E. Post-collection processing of Schirmer strip-collected human tear fluid impacts protein content. Analyst. 2012;137(21):5088–5096. DOI: 10.1039/c2an35821b
27. Ситник Г.В., Камышников В.С., Лебедева П.А. и др. Лабораторное исследование слезной жидкости на основе использования стандартизованной технологии ее забора и пробоподготовки: результаты валидации способа взятия биологической жидкости. Лабораторная диа­гностика. Восточная Европа. 2021;10(4):483–492. DOI: 10.34883/PI.2021.10.4.009Sitnik H., Kamyshnikov V., Lebedeva P. et al. Laboratory Study of Tear Fluid Based on the Use of a Standardized Technology for Its Collection and Sample Preparation: Results of Validation of the Method for Taking Biological Fluid. Laboratory Diagnostics. Eastern Europe. 2021;10(4):483–492 (in Russ.). DOI: 10.34883/PI.2021.10.4.009
28. Борзилова Ю.А., Болдырева Л.А., Валеева Р.Р. и др. Уровень VEGF-A в слезной жидкости у пациентов с диабетической ретинопатией в различные сроки после панретинальной лазеркоагуляции. Медицинский альманах. 2016;1:100–103.Borzilova Yu.A., Boldyreva L.A., Valeeva R.R. et al. The level of VEGF-A in lacrimal fluid in patients with diabetic retinopathy at various times after panretinal laser coagulation. Medicinskij al'manah. 2016;1:100–103 (in Russ.).

License Creative Commons
This work is licensed under a Creative Commons «Attribution» 4.0 License.


Previous article
Next article