Russian Medical Inquiry
(RMZh. Meditsinskoe Obozrenie) ISSN 2587-6821 (Print), 2686-9918 (Online)

New model of temporary keratoprosthesis

VAK

Scopus

E-libraryDimensions

russian citation indexULRICHS

roaddoaj

CyberleninkaGoogle Scholar

vinitiResearch4life

MendeleyScilit

РГБWhite list




Open accessCrossrefAntiplagiat

RMJ.ru




DOI: 10.32364/2311-7729-2025-25-Suppl-18

A.D. Chuprov1,2, A.A. Gorbunov1, I.N. Dmitriev3, I.M. Yartsev3, V.A. Trubnikov1,2, D.A. Razdobreev2, Yu.A. Shcherbanova1, A.S. Maksyutov1

1Orenburg Branch of the S. Fyodorov Eye Microsurgery Federal State Institution, Orenburg, Russian Federation

2Orenburg State University, Orenburg, Russian Federation

3OOO "MIKVID", Nizhny Novgorod, Russian Federation

Aim: to develop a medical device for temporary closure of a surgical wound in the cornea during a reconstructive surgery on the eyeball and to study its physical properties.

Materials and Methods: a pilot sample of temporary keratoprosthesis is made of polycarbonate by thermal compression. The body design provided sealing of the surgical wound and reduced a risk of complications. To study the structure, optical microscopy (Olympus CKX-41 microscope) and atomic force microscopy (СMM-2000 AFM microscope) were used. The pilot sample of temporary keratoprosthesis was tested in cadaver pig eyes.

Results: polycarbonate has demonstrated excellent mechanical properties, high transparency, heat and ultraviolet resistance. The pig eye tests demonstrated reduced device insertion time and minimal trauma to eye tissue. The prosthesis provided tight fit and sealing, and high transparency provided retinal imaging. Surface examinations by optical and atomic force microscopy revealed the material homogeneity with minimal subvisible particulate matter. Surface roughness factors were in the nanometer range. The spectral measurement confirmed photostability of the material when exposed to visible light, and no destructive changes were found in the polymer chains. As the polymer retained its properties and dimensions after hours-long irradiation, this indicates its mechanical and photochemical resistance.

Conclusion: the study confirmed that, due to strength, durability and high transparency, polycarbonate is a highly efficient material for temporary keratoprosthesis. The cadaver pig eye test demonstrated tight fit, ocular cavity sealing and reduced injury rate. The identified absorption regions in the ultraviolet range do not affect real-world application of the device.

Keywords: ophthalmology, temporary keratoprosthesis, 3D modeling, thermal compression, medical device

For citation: Chuprov A.D., Gorbunov A.A., Dmitriev I.N., Yartsev I.M., Trubnikov V.A., Razdobreev D.A., Shcherbanova Yu.A., Maksyutov A.S. New model of temporary keratoprosthesis. Russian Journal of Clinical Ophthalmology. 2025;25(Special Issue):123–130 (in Russ.). DOI: 10.32364/2311-7729-2025-25-Suppl-18

About the authors:

Alexander D. Chuprov — Dr. Sc. (Med.), Professor, Director of the Orenburg Branch of the S. Fyodorov Eye Microsurgery Federal State Institution; 17, Salmyshskaya str., Orenburg, 460047, Russian Federation; Head of the Department of Biomedical Engineering, Orenburg State University; 13, Pobedy ave., Orenburg, 460018, Russian Federation; ORCID iD 0000-0001-7011-4220

Alexey A. Gorbunov — C. Sc. (Med.), Assistant Professor, Deputy Director for Medical Work of the Orenburg Branch of the S. Fyodorov Eye Microsurgery Federal State Institution; 17, Salmyshskaya str., Orenburg, 460047, Russian Federation; ORCID iD 0000-0003-3166-4419

Il'ya N. Dmitriev — Leading Engineer, OOO ''MIKVID''; 39, Gagarin ave., Nizhny Novgorod, 603009, Russian Federation; ORCID iD 0009-0006-6275-204X

Ivan M. Yartsev — Leading Engineer, OOO ''MIKVID''; room 17a, office 4, 39, Gagarin ave., Nizhny Novgorod, 603009, Russian Federation; ORCID iD 0009-0005-0726-3633

Vyacheslav A. Trubnikov — C. Sc. (Med.), Deputy Director for Innovative Development of Medical Technologies, Orenburg Branch of the S. Fyodorov Eye Microsurgery Federal State Institution; 17, Salmyshskaya str., Orenburg, 460047, Russian Federation; Senior Lecturer, Department of Biomedical Engineering, Orenburg State University; 13, Pobedy ave., Orenburg, 460018, Russian Federation; ORCID iD 0000-0002-9451-8622

Dmitryi A. Razdobreev — C. Sc. (Chem.), Assistant Professor of the Department of Biophysics and Condensed Matter Physics, Orenburg State University; 13, Pobedy ave., Orenburg, 460018, Russian Federation; ORCID iD 0000-0002-7749-0074

Yulia A. Shcherbanova — Ophthalmologist, Orenburg Branch of the S. Fyodorov Eye Microsurgery Federal State Institution; 17, Salmyshskaya str., Orenburg, 460047, Russian Federation; ORCID iD 0009-0001-4864-1988

Azamat S. Maksyutov — Ophthalmologist of Orsk Medical and Diagnostic Department of the Orenburg Branch of the S. Fyodorov Eye Microsurgery Federal State Institution; 17, Salmyshskaya str., Orenburg, 460047, Russian Federation.

Contact information: Yulia A. Shcherbanova, e-mail: nauka@ofmntk.ru

Financial Disclosure: no authors have a financial or property interest in any material or method mentioned.

There is no conflict of interest.

Received 13.12.2024.

Revised 15.01.2025.

Accepted 07.02.2025.

References
1. Fagerholm P., Lagali N.S., Ong J.A. et al. Stable corneal regeneration four years after implantation of a cell-free recombinant human collagen scaffold. Biomaterials. 2014;35(8):2420–2427. DOI: 10.1016/j.biomaterials.2013.11.079
2. Yaghouti F., Nouri M., Abad J.C. et al. Keratoprosthesis: preoperative prognostic categories. Cornea. 2001;20(1):19–23. DOI: 10.1097/00003226-200101000-00003
3. Basu S., Taneja M., Narayanan R. et al. Short-term outcome of Boston Type 1 keratoprosthesis for bilateral limbal stem cell deficiency. Indian J Ophthalmol. 2012;60(2):151–153. DOI: 10.4103/0301-4738.94059
4. Горбунов А.А., Казеннов А.Н., Щербанова Ю.А., Мамбетова Э.М. Клинический случай одномоментного лечения отслойки сетчатки со сквозной кератопластикой. Оренбургский медицинский вестник. 2021;9(4(36)):60–64.Gorbunov A.A., Kazennov A.N., Shcherbanova Yu.A., Mambetova E.M. Clinical case of one-stage surgical treatment of retinal detachment with penetrating keratoplasty. Orenburg Medical Herald. 2021;9(4(36)):60–64 (in Russ.).
5. Кански Дж.Дж., Милевски С.А., Дамато Б.Э., Тэннер В. Заболевания глазного дна. М.: МЕДпресс-информ; 2024.Kanski J.J., Milewski S.A., Damato B.E., Tanner V. Diseases of the ocular fundus. Moscow: MEDpress-inform; 2024 (in Russ.).
6. Chodosh J., Ilios E.P., Graney J. Keratoprothesis apparatuses, systems, and methods: U.S. Patent WO2017177145A1. Washington, DC: U.S. Patent dated 2017.
7. Зейнеп А. Кератопротезирование в сочетании с витрэктомией. Точка зрения. Восток — Запад. 2019;(4):80–81. DOI: 10.25276/2410-1257-2019-4-80-81Zeynep A. Keratoprothesis Combined with Vitrectomy. Point of view. East-West. 2019;(4):80–81 (in Russ.). DOI: 10.25276/2410-1257-2019-4-80-81
8. Чупров А.Д., Горбунов А.А., Щербанова Ю.А. Временный кератопротез. Патент РФ на полезную модель № 205904. Опубл. 21.05.2021. Бюл. № 23.Chuprov A.D., Gorbunov A.A., Shcherbanova Yu.A. Temporary keratoprosthesis. Patent RU № 205904. Punlished May 21, 2021. Bull. № 23. (in Russ.).
9. Ghaffariyeh A., Honarpisheh N., Karkhaneh A. et al. Fyodorov-Zuev keratoprosthesis implantation: long-term results in patients with multiple failed corneal grafts. Graefes Arch Clin Exp Ophthalmol. 2011;249(1):93–101. DOI: 10.1007/s00417-010-1493-8
10. Якименко С.А., Родин С.С., Левицкая Г.В., Уфанец Н.Н. Опыт использования временного кератопротеза для проведения витрэктомии у пациентов с бельмами роговицы и отслойкой сетчатки. Проблеми екологічної та медичної генетики і клінічної імунології. 2011;106(4):32–36.Yakimenko S.A., Rodin S.S., Levytska G.V., Umanets N.N. Vitrectomy with temporary keratoprosthesis in patients with retinal detachment and corneal opacity. Problems of ecological and medical genetics and clinical immunology. 2011;106(4):32–36 (in Russ.).

License Creative Commons
This work is licensed under a Creative Commons «Attribution» 4.0 License.


Previous article
Next article